"La Garonne" social housing in Toulouse: aiming for an "A" energy rating using the Dualsun and Heliopac solar combination

  • 2026
  • Toulouse, France
  • Power output : 76.5 kWp
  • Panels : 180 Dualsun hybrid panels

An exceptional renovation project is underway in Toulouse, in the heart of the Empalot district.

The La Garonne residence—an iconic 10-story building constructed in 1961 and affectionately nicknamed “La Banane” (The Banana) due to its curved shape—is enjoying a true second life. Spearheaded by the social housing provider Toulouse Métropole Habitat, this major renovation project is modernizing the living environment for the building’s 197 units while delivering outstanding bioclimatic performance. With official commissioning scheduled for the fourth quarter of 2026, our hybrid solar solution is poised to prove its worth once again.

Here is a look at this project, which features the Heliopacsystem+ solution, developed jointly by Dualsun and HELIOPAC, incorporating 184 hybrid panels!

To successfully carry out this project with an overall budget of €23.6 million, Toulouse Métropole Habitat opted for an innovative design-build contract with a multi-year performance guarantee. This is where the engineering firm BEMING INGENIERIE comes in, providing technical project management, while the Climater Group deploys all its expertise as installer and maintenance manager to bring this cutting-edge system to life. The main objective is to upgrade the residence to a very low-energy building status by raising its EPC (Energy Performance Certificate) rating to level A, the highest performing level on the market.

 

The technical solution: the intelligent coupling of Dualsun + heliopacsystem+®

To achieve such high energy sobriety for Domestic Hot Water (DHW) needs, which represent a net requirement of 240,845 kWh per year, the technical solution relies on the installation of 180 Dualsun hybrid solar panels combined with heliopacsystem+® technology.

On the roof of the residence, the installation deploys 374.4 m² of catchment area, representing an installed photovoltaic capacity of 76.5 kWp. To adapt perfectly to the constraints of the flat roof while maximizing compactness, the 180 panels are installed in landscape layout on Fix Evo Tilt heat-welded blocks, guaranteeing excellent mechanical strength and preserving the building’s watertightness.

The boiler room infrastructure was designed for maximum efficiency and is divided into two separate technical rooms:

  • The first room is entirely dedicated to energy storage, housing 4 tanks of 3,000 L each (amounting to a storage volume of 12,000 liters).

  • The second room brings together the generation and control equipment, namely 4 x 14 kW heat pumps (HP), the interconnection with the district heating network, and the entire regulation system.

The operation of the whole system is based on a particularly clever self-consumption synergy:

  • Boosted thermal production: The thermal backside of the 180 Dualsun hybrid panels recovers solar and environmental calories. This glycol fluid supplies 248,939 kWh/year of renewable thermal energy directly to the heat pumps. Thanks to this input, the heat pumps display remarkable efficiency and cover almost all needs by producing 340,193 kWh/year of heat. The city of Toulouse’s district heating network (with a backup capacity of 380 kW) only steps in as a last resort.

  • Local and intelligent electricity: The photovoltaic front side generates 96,673 kWh of green electricity per year. Around 36% of this electricity is directly self-consumed to power the heat pumps and the auxiliaries of the heliopacsystem+® setup, while the remaining 64% is injected into the building’s grid to reduce the energy bill for the common areas.

  • Zero waste thanks to thermal storage: To maximize self-consumption and ensure no kWh from the 76.5 kWp installation is wasted, the system integrates 48 kW of immersion heaters on the storage tank side (distributed as 2×12 kW + 4×6 kW). Their role is strategic: using the surplus photovoltaic production to heat the water in the storage tanks directly as soon as solar production exceeds the instantaneous needs of the heat pumps.

Behind the scenes of the sizing study

To accurately measure the scale of this setup, the simulation data from this document highlight the reality of the residence’s needs. The building accommodates a high family density with a mix of 97 x 3-room (T3), 90 x 4-room (T4), and 10 x 5-room (T5) apartments.

For all these households, the nominal daily consumption of domestic hot water reaches a volume of 15.72 m³ per day (i.e., 15,720 liters distributed daily) at a strict setpoint temperature of 55°C. The study also factor in natural heat losses from the distribution circuit, estimated at 288 kWh per day (or 105,120 kWh per year). This constant and demanding flow is exactly what the Dualsun + Heliopac coupling successfully absorbs.

“Fonds Chaleur” and Title V: for a profitable and compliant project

Beyond its pure technical performance, choosing the heliopacsystem+® solution with Dualsun panels relies on first-rate regulatory and financial arguments. The system benefits from double recognition:

  • ADEME support: The coupling is eligible for the Fonds Chaleur (Heat Fund), a key lever that funds a significant share of investment costs for landlords and project owners.

  • Regulatory compliance: The system is validated by a Title V approval, guaranteeing it is fully accounted for in RE2020 calculations for new builds as well as major renovations.

This double technical and financial validation makes it the ideal solution for multi-family housing, combining environmental performance, drastic cost reductions, and absolute regulatory compliance.

The benefits: a quantified, win-win impact

The strength of this exemplary rehabilitation lies in its cross-cutting positive impacts, benefiting all project stakeholders:

  • For the tenants: Replacing old gas cookers with vitroceramic hobs completely eliminates gas from the apartments. Combined with the efficiency of the solar system, which draws free energy from the environment, monthly hot water charges are drastically and permanently reduced for the residents of the 197 housing units.

  • For the social landlord (Toulouse Métropole Habitat): Thanks to commissioning and performance monitoring, the landlord benefits from a performance guarantee. The property asset is upgraded with an overall renewable energy coverage rate reaching 82% of the total DHW requirement.

  • For the planet: It is undoubtedly on the environmental front that the figures speak loudest. Where a conventional gas installation would emit 80.6 tonnes of $CO_2$ per year, the heliopacsystem+® solution with Dualsun panels emits only 10 tonnes.

    The result? A colossal saving of 71 tonnes of $CO_2$ avoided each year, equivalent to 280,632 km driven by car!

In conclusion, the bioclimatic transformation of the La Garonne residence brilliantly demonstrates that it is possible to combine architectural renovation, lower charges for tenants, and high-level environmental performance.

By bringing together the technical expertise of BEMING INGENIERIE, the installation precision of the Climater Group, and the technological performance of Dualsun and Heliopac, this project stands as a benchmark for the energy transition in multi-family housing. See you at the end of 2026 to monitor the first real-world performances!

Gif credit: Toulouse Métropole Habitat

Technical information

Characteristics 197 social housing units
Number of panels 180 Dualsun hybrid solar panels
Power output 76.5 kWp
Rooftop installation south-facing, 30° tilt
Thermal system Heliopac System+
Photovoltaic system Installation on heat-welded mounts using the Fix Evo Tilt system, landscape orientation; inverters; self-consumption with sale of surplus electricity.